Tag List: The Tags you have created in the Modbus Rtu section will be placed at the top of this list automatically. From the right click menu you can add SQL Tags or Internal Tags to the datagrid.
Connection on/off: Two buttons which are visible on the Toolbar when this window is open. Tag manager communicates with the tags via this buttons in order to reading and writing data. During the communication many function in this windows is disabled. When communication enabled they became active.
Tag list information:
Network info: Indicates Tags group property.
Tag name: Indicates tags name. When first created random name assigned automaticaly. This name can be changed later. Then all list controlled if there is same named Tag exists.
Value Type: Type of value selected here.
Value: This is for the monitoring Tag's last value.
Historical: You must activate this when you want to save historical datas in order to monitoring on the chart or any other reason. So Tag's value will be saved to SQL Server at every cycle. Activating many Tag's unnecessarily makes adversely effect to the performance and database size.
SQL Tag’ları: All Tags can be connected to SQL server historically. Sql Tag reads Tags value from the SQL Server and writes to it. The first line of database table is used for this. If this Tag historical every value saved to new line. But as input/output the first line is used.
Bit In Tag: Boolean Auxiliary Tags that you can connect to the Bits of the Integer Tags. The Auxiliary Tag you create with this command works with the selected bit of main tag. Auxiliary tag value will change automatically if connected bit changes when main tag changed. In the same way even though main tag doesn't change if auxiliary tag changes WinTr recalculates the main tag's value and changes it if necessary. Auxiliary tags are the internal tags. There is no limit for use them.
Internal Tagler: No limited Tags that can be used for the internal operations.
Line Color: No colored line means everything allright. Red line means the connection can not be established.
Referance: You can see many information about the Tags at the box which is at the right side of the page. At this operations scripts are not examined. So you must review the tags used in the scripts separately.
Unused: Generates the list of tags that on the list but used nowhere.
Cannot found: Generates the Tag list which are used in the Project but not exist on this list. This means Tag deleted from this list or renamed after used in the project.
Synchronous Tag List: Generates the list of the synchronized tags of WinTr Client stations and WinTr Server stations.
Synchronous Tag Test: Tests the compliance of the synchronized tags of WinTr Client stations and WinTr Server stations. To do this connects the server and compares tag names and value types.If it finds an error generates a list. The server will completely disabled which has an error. You can find further information at Control Panel section.
Cross Referance: Generates the list of the places where used selected Tag.
Status: Tag number Indicator placed at the bottom. Software is sold by External Tag number.
SQL Tag Building: System automatically checks sql connections when you change Tags or modify Datatypes from the Tag list or other tabs. If modification effects SQL configuration "SQL Tag Bulider" prompted with the warning. When this warning activated necessariyl change made in the database. This doesn't executed auomatically. Because historical values of removed Tags or Datatype changed Tags are erased. This effects only the Tags worked on.